shi yong yu ctcs-3 ji de an quan ji suan ji ping tai de wu xian an quan tong xin jia gou fen xi
Author(s): HUANG Binbin, MENG Qingyao
Pages: 33-
35,36
Year: 2016
Issue:
4
Journal: Railway Signalling & Communication Engineering
Keyword: train-ground communication; safety communication; safety platform; data splice;
Abstract: ATP onboard equipment in CTCS-3 system communicates with RBC through the subset-037 safety communication protocol. Subset-037 safety communication carries the safety of train communication data and should meet the SIL4 level standard. The paper puts forward a safety platform architecture design method for realizing train-ground safe communication and analyzes the feasibility of the method based on the relevant functional points. The results shows that the method has practical value to guide train-ground safety communication.