Determination of Aluminium in Serum by Dry Ashing-CAS Spectrophotometry
Author(s): 
Pages: 35-38
Year: Issue:  8
Journal: GUANGDONG TRACE ELEMENTS SCIENCE

Keyword:  血清灰化CAS;
Abstract: 建立了一种快速、灵敏测定血清铝的分光光度方法.血清标本经灰化处理后,在表面活性剂CP C存在下,用铬天青S(CAS)作显色剂测定血清铝,线性范围0~7.4 μmol/ L,平均回收率为100.6%,批内变异系数(CV)和批间变异系数分别为0.028 和0.037,与 Al-CAS络合法比较具有良好的相关性,y=0.990 2x-0.013 0,r =0.997 7,P》0.05.42例健康人血清铝含量为0.92~4.16 μmo l/L(±2 s).用本法测定血清铝方法简便、灵敏可靠, 适合临床应用.