The server is under maintenance between 08:00 to 12:00 (GMT+08:00), and please visit
later.
We apologize for any inconvenience caused
Efficiency Analysis of Boiler of 600MW Supercritical Thermal Power Generator Set
Author(s): WANG Yusi, XIA Jiaqun, HE Haohao, HE Haoran
Pages: 5-
8,25
Year: 2016
Issue:
1
Journal: Industrial Heating
Keyword: 600 MW thermal power generator set; supercritical; thermal efficiency analysis; exergy efficiency analysis; energy saving;
Abstract: 采用热平衡和(火用)平衡分析方法对电站锅炉系统进行了热平衡和(火用)平衡分析,通过实测、计算和分析,得到某电厂锅炉的热效率为92.48%,(火用)效率为59.89%,主要热损失为排烟损失和炉体散热损失;主要(火用)损失为传热(火用)损失和燃烧(火用)损失.针对电站锅炉热平衡和(火用)平衡中各种损失及其产生的部位,结合某电站锅炉的实际状况,提出了相应的减少有关损失的改进措施,以进一步提高电站锅炉的能源利用率.
Citations
No citation information