The server is under maintenance between 08:00 to 12:00 (GMT+08:00), and please visit
later.
We apologize for any inconvenience caused
The Fire Smoke Control Numerical Simulation of Deeply Buried Long Tunnel under the Way of Setting Intermediate Air Shaft
Author(s): XIE Xuan, FENG Lian, ZHANG Zuo, LIU Jiang, LIAO Kai
Pages: 126-
129
Year: 2013
Issue:
2
Journal: Refrigeration & Air Conditioning
Keyword: intermediate air shaft; push-pull ventilation; tunnel fire; CFD;
Abstract: 采用计算流体力学(CFD)方法,对设置中间风井方式下的隧道火灾通风排烟进行数值模拟研究.选取火灾发生在斜井B与竖井C之间,着重研究不同风井风机送排风风量对火灾防排烟的影响.隧道内列车发生火灾,开启事故列车两端风井内风机进行推挽式通风,可以满足人员逃生路径上无烟要求.事故列车后方有阻塞列车时,由于列车的阻塞作用,对斜井B内的隧道风机在往事故段隧道组织气流更加有利.对于深埋长隧道而言,设置中间竖井难度大,成本高,利用隧道临时施工竖井或斜井进行后期改造,即可满足通风与排烟的要求,又节省大部分土建投资.
Citations
No citation found
Related Articles