The server is under maintenance between 08:00 to 12:00 (GMT+08:00), and please visit later.
We apologize for any inconvenience caused
Login  | Sign Up  |  Oriprobe Inc. Feed
China/Asia On Demand
Journal Articles
Laws/Policies/Regulations
Companies/Products
Hydrodynamic Effects of the Oxidation Ditch on the Removal Efficiency and Energy Consumption
Author(s): 
Pages: 2323-2326
Year: Issue:  11
Journal: ENVIRONMENTAL SCIENCE

Keyword:  氧化沟水力特性能耗处理效果;
Abstract: 氧化沟水力特性对沟内溶解氧浓度和混合液流速梯度分布影响很大,可对最终的处理效果和能耗产生重要的影响.以处理能力500m3/d的单沟型Passver氧化沟为例,对沟内的流场分布进行了计算模拟与实测,提出了改善氧化沟水力特性的措施,并分析了改善措施对运行能耗的影响,结果表明,在曝气转刷下游的弯道处分别设置张角90°,150°,180°的导流墙均可降低局部阻力,且随着张角的增大,效果越为显著,当张角为180°时,可降低局部能耗10%左右;在转刷转速72 r/min的条件下,增设张角180°的导流墙不会对溶解氧的分布产生较大影响.根据氧化沟处理低浓度生活污水的实际运行结果,采用活性污泥模拟软件对水力特性改善前后的处理效果进行了模拟计算,结果表明,设置导流墙前后出水水质变化不大.
Related Articles